Simscape Electrical conversion to Simulink and back
13 ビュー (過去 30 日間)
古いコメントを表示
Hello,
I have used Simulink for a long time but I am new to Simscape. I am trying to build a model of a DC motor controlled using a H Bridge. Just to try something out, I want to connect the BRK port of the H Bridge to a signal coming from Simulink, using the Simulink-PS convertor block. But I am unable to do so as you can see in the attached picture.
Is this not the right way to connect Simulink to PS?
Thanks,
Anish
0 件のコメント
採用された回答
David John
2021 年 12 月 6 日
BRK is an electrical signal, so it needs to come out of a voltage source instead of directly from a Simulink-PS Converter.
Try adding a Controlled Voltage Source between REF and BRK, and connect your Physical Signal to the control node.
0 件のコメント
その他の回答 (0 件)
参考
カテゴリ
Help Center および File Exchange で Specialized Power Systems についてさらに検索
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!