Increasing xcorr() resolution
3 ビュー (過去 30 日間)
古いコメントを表示
Hello,
Is there a wa y to increase the "resolution" of xcorr?
Something like zero padding for the fft()
Thanks,
Patrick
0 件のコメント
採用された回答
Daniel Shub
2011 年 4 月 28 日
Zero padding will increase the frequency resolution (i.e., reduce the spacing between frequency components), but does not affect the temporal resolution (the time between samples). The resample function increases the temporal resolution, but does not affect the frequency resolution.
a = [0, 0, 1, 0, 1, 0, 0];
b = [0, 0, 1, 1, 1, 0, 0];
upFactor = 10;
aUp = resample(a, upFactor, 1);
bUp = resample(b, upFactor, 1);
[r, lags] = xcorr(a, b, 'coeff');
[rUp, lagsUp] = xcorr(aUp, bUp, 'coeff');
lagsUp = lagsUp/upFactor;
plot(lags, r, 'b', lagsUp, rUp, 'r');
It you do not want a normalized cross-correlation, you will need to scale rUp.