Minimum input data resolution

2 ビュー (過去 30 日間)
Charitha Buddhika Heendeniya
Charitha Buddhika Heendeniya 2020 年 7 月 22 日
Dear all,
I'm trying to use the system identification toolbox for the first time for characterizing a microgrid. While preparing the input data for the model (in this case I have 1 second time resolution data), I asked myself whether or not this time resolution I have is sufficient or not. Can any of you provide me with some insight as to how I could try to asnwer this question?
Of course, it is not practical for me to get data with higher time resolution than 1 second. But even in this case, I would like to have a feeling to what kind of inaccuracies that I might get for not having a higher time resolution. How can I get an estimation on this before starting the modeling process?
regards
Buddi

採用された回答

Rajiv Singh
Rajiv Singh 2020 年 7 月 22 日
Look up Nyquist Sampling Theorem. If you are sampling (hopefully with anti-aliasing) at 1Hz then you cannot theoretically capture dynamics higher than 0.5 Hz. Some (may be subtle) aspects:
  • This is in linear case only.
  • In practice it is good to keep sampling 5-10 times faster than the highest frequency in the system that you are interested in capturing.
  • This is in absence of any additional priors; otherwise: look up compressed sensing literature.
  1 件のコメント
Charitha Buddhika Heendeniya
Charitha Buddhika Heendeniya 2020 年 7 月 23 日
Thanks Rajiv

サインインしてコメントする。

その他の回答 (0 件)

カテゴリ

Help Center および File ExchangeLinear Model Identification についてさらに検索

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by