Hi Please,when i generate to code to TI C2000, What type of configuration does simulink need for the generate algorithm code, with all chart conditions?
I'am using Chart for control algorithm, and I need send the code generation for TI C2000, through code generatios of simulink window.
I can a generate code, but I look that generated code is missing several conditions and operations.
If the issue is just that some states and/or transitions you have programmed in Stateflow do not appear in the generated code, then I just think the Embedded Code generator optimized those states out of the code since they are never reached or used. This aspect of the code generator is called 'block reduction'.
If you have a transition with the condition [false] for example, the transition is never made and the code generator may chose to not generated code of it.
I try to send this contol algorithm into TI C2000 (TMS320F28379D LAUNCHPAD)
This is my control algorihtm.
Inputs/outputs (V,P/D)Variables (dP,dV,Vp,Pp), Initial Value (Vp=20,Pp=0,D=0.8)
when in simulink I generate the code c, these compilation errors appear for this variables
This assignment writes a 'uint16' value into a 'double' type. Code generation does not support changing types through assignment. Check preceding assignments or input type specifications for type mismatches. State 'Save_Data'"Pp" "Vp"
You know which configuration I needed for generated C code of my algorithm.
You can also select a web site from the following list:
How to Get Best Site Performance
Select the China site (in Chinese or English) for best site performance. Other MathWorks country sites are not optimized for visits from your location.
1 件のコメント
このコメントへの直接リンク
https://jp.mathworks.com/matlabcentral/answers/563510-help-with-code-generation-for-ti-c2000#comment_934067
このコメントへの直接リンク
https://jp.mathworks.com/matlabcentral/answers/563510-help-with-code-generation-for-ti-c2000#comment_934067
サインインしてコメントする。