Store a videoinput in a Data Store Memory block in Simulink
2 ビュー (過去 30 日間)
古いコメントを表示
Hello,
I'm trying to store a videoinput in a DataStoreMemory, so I can access it out of a Embedded MATLAB Function (fcn) block. I set the type to an expression (videoinput). But I got an error:
Error evaluating parameter 'OutDataTypeStr' in 'DataStoreImage/VideoInputDataStore': ADAPTORNAME and DEVICEID must be specified.
Can you help me? If I missed necessary information, please tell me.
Thanks Timo
0 件のコメント
採用された回答
Kaustubha Govind
2011 年 4 月 15 日
I believe Data Store Memory only supports numeric types (see Section "Data type" on the documentation page).
0 件のコメント
その他の回答 (3 件)
Shankar Subramanian
2011 年 4 月 22 日
Hi Timo,
Writing your own MATLAB function (using videoinput and getdata) and bringing into SIMULINK will not necessarily help you with the rate. You should actually run the script suggested here to calculate the frame rate in MATLAB.
The From Video Device block does not add any performance overhead and performs at par with the rate achievable within MATLAB using the hardware.
Thanks
Shankar
0 件のコメント
Timo
2011 年 4 月 15 日
1 件のコメント
Kaustubha Govind
2011 年 4 月 20 日
Are you using the MATLAB Fcn block? You could try using persistent variables.
参考
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!