When is the 'ModelReferenceVersionMismatchMessage' Simulink model parameter editable?
7 ビュー (過去 30 日間)
古いコメントを表示
I would like to disable the "ModelReferenceVersionMismatchMessage" parameter, but when I go to the configuration parameters, it's greyed-out and I can't modify it. When I try to edit it from the command line, I also receive errors:
The documentation page for this parameter doesn't give any hints as to when it is possible to actually edit it. How can I edit it?
0 件のコメント
採用された回答
Fangjun Jiang
2020 年 4 月 9 日
Try this
model='sldemo_mdlref_basic';
open_system(model);
get_param(model,'ModelReferenceVersionMismatchMessage')
set_param(model,'ModelReferenceVersionMismatchMessage','warning')
set_param(model,'ModelReferenceVersionMismatchMessage','none')
3 件のコメント
Fangjun Jiang
2020 年 4 月 20 日
Yes. In the .tlc file, you can disable certain configuration parameters. Open the .tlc file to see if you can find the source.