Problem with powergui in reference model

7 ビュー (過去 30 日間)
Raditya Arrizki Dewantara
Raditya Arrizki Dewantara 2020 年 4 月 1 日
回答済み: Lin Shaun 2021 年 6 月 8 日
Hello everyone
I have a simulation which currently requires me to have a reference model which has a faster sampling rate than the rest of the simulation. I need to measure the voltage in this model thus require to put another powergui block inside it. But now I'm getting this error
"Invalid run-time parameter registration in S-function 'sfun_spssw_discc' in model 'FPGA'. An S-function can register run-time parameters only if the S-function is being inlined. To be able to reference the model 'FPGA', the S-function 'sfun_spssw_discc' needs to set the option SS_OPTION_USE_TLC_WITH_ACCELERATOR and it needs to have a TLC file."
Not really sure how to solve this issue, any advice would be very appreciated!

回答 (1 件)

Lin Shaun
Lin Shaun 2021 年 6 月 8 日
"powergui", "Preferences", "Use TLC file when in Accelerator Simulation Mode and for code generation".