I have a design and simulated it using Simulink. Its components belong to the SimPowerSystems blocks. When I am simulating it, I get an error and the simulation halts in the middle. The error message reads
unable to reduce step size without violating a step size of 7.3834....e-17 at 0.2034... s
I tried changing the relative tolerance in the configuration parameters, that did not work.
0 件のコメント
採用された回答
Sebastian
2011 年 1 月 27 日
The "Choosing an Integration Algorithm" section of the SimPowerSystems documentation contains some hints on which solver parameters to tweak, in particular if switches and Power Electronics devices are in the model: http://www.mathworks.com/access/helpdesk/help/toolbox/physmod/powersys/ug/f7-7663.html#f7-7664
1 件のコメント
Todd Flanagan
2011 年 1 月 28 日
Arvind says, "Thank you. I had to tweak a few parameters in the solver configuration parameters and make minor changes in my circuit component values and it worked. I also changed the solver to Ode23tb instead of Ode23t."