How to reset a stateflow state machine on external event?

Is it possible to re-initialize a state machine on an event generated by an other state machine?

 採用された回答

TAB
TAB 2012 年 9 月 3 日

1 投票

AFAIK, there is no such provision in stateflow. But you can design your stateflow chart logic with an external trigger input in such a way that it resets all the states and data (locals & outputs) when trigger is enabled.

2 件のコメント

Kaustubha Govind
Kaustubha Govind 2012 年 9 月 4 日
編集済み: John Kelly 2015 年 2 月 26 日
The documentation also suggests placing Stateflow charts inside Enabled Subsystems and setting the "States when enabling" parameter to "reset" to force re-initialization: http://www.mathworks.com/help/stateflow/ug/controlling-states-when-function-call-inputs-reenable-charts.html?searchHighlight=States%20when%20enabling
Song
Song 2016 年 2 月 10 日
Do you have a example of this? That would be extremely helpful

サインインしてコメントする。