Thermal network transformation: Foster fourth order to Cauer first order?
9 ビュー (過去 30 日間)
古いコメントを表示
Hello, in the symscape power systems example "Loss Calculation in a Three-Phase 3-Level Inverter" there's a block of a half-bridge IGBT with loss calculation. I wanted to know how you calculated the junction to case thermal resistance and the junction thermal capacitance for this block, since the manufacturer’s datasheet only gives the R and C parameters of a fourth order Foster network, and from what I see in the example the junction to case thermal resistance and the junction thermal capacitance correspond to a first order Cauer representation.
0 件のコメント
採用された回答
Carlos Rueda
2019 年 12 月 19 日
移動済み: Sabin
2022 年 12 月 23 日
A method to find the equivalent Cauer network from the fourth-order Foster network is shown in Appendix A of book "Transient Electro-Thermal Modeling of Bipolar Power Semiconductor Devices" by Gachovska et al.
0 件のコメント
その他の回答 (1 件)
Joel Van Sickel
2020 年 8 月 24 日
Moving Carlos Rueda's answer down here to clean up which questions are flagged as unanswered.
A method to find the equivalent Cauer network from the fourth-order Foster network is shown in Appendix A of book "Transient Electro-Thermal Modeling of Bipolar Power Semiconductor Devices" by Gachovska et al.
0 件のコメント