Simulink sample time with external sample clock?
1 回表示 (過去 30 日間)
古いコメントを表示
Hi,
I want to run a S&H block with an external sample pulse. I am simulating a mixed signal digital PLL for a motor control. The phase detector is using boolean logic elements and is run from a 5Mhz pulse generator. The phase detector generates a phase count and a sample pulse about every 360Hz. I need this to drive a digital filter but am unclear how to use my boolean 360Hz sample pulse to act as the sample time for my z-domain digital filter.
Thanks ~
![Matlab_question.png](https://www.mathworks.com/matlabcentral/answers/uploaded_files/230251/Matlab_question.png)
0 件のコメント
採用された回答
Jonas
2019 年 7 月 18 日
I would suggest to put the digital filter in a triggered subsystem and use the 360 Hz signal as trigger.
その他の回答 (0 件)
参考
製品
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!