phasor vs continuous simulation
19 ビュー (過去 30 日間)
古いコメントを表示
running 'power_dynamicload' from the command line brings up the model of the dynamic load example.
1] running it in phasor and continuous mode yields totally different results for the positive current sequence (scope 1). I thought differences only arose for simulations of systems with power electronics. Am i missing something???
2] To change the P and Q values for the load block, according to the literature i gotta do it from the machine initialize tab. I tried doing so but it doesn't update the blocks. Also trying to 'update the system' returns an answer saying solution cannot be found. Some help here pls!
0 件のコメント
回答 (1 件)
Sabin
2022 年 12 月 20 日
The way phasor simulation is working is different to the time-simulation (discrete or continuous). The phasor solve a much simpler set of algebraic equations relating the voltage and current phasors. See Introducing the Phasor Simulation Method for more insights.
0 件のコメント
参考
カテゴリ
Help Center および File Exchange で Electrical Sensors についてさらに検索
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!