Info

この質問は閉じられています。 編集または回答するには再度開いてください。

Function-Call generator does not accept Simulink Parameter

1 回表示 (過去 30 日間)
Vamsinag Gunti
Vamsinag Gunti 2019 年 2 月 6 日
閉鎖済み: MATLAB Answer Bot 2021 年 8 月 20 日
Hi Community,
I am using the Value of a Simulink Parameter as the sample time in the function-call generator. However, I am getting the following error:
Error evaluating parameter 'sample time' in 'MyModel/Function-Call Generator'
Caused by:
  • Struct contents reference from a non-struct array object.
For the sample time I use the value of a simulink parameter:
mySimulinkParameter =
Parameter with properties:
Value: 0.0020
CoderInfo: [1×1 Simulink.CoderInfo]
Description: ''
DataType: 'single'
Min: 0.0010
Max: 1
Unit: ''
Complexity: 'real'
Dimensions: [1 1]
I.e, I enter
mySimulinkParameter.Value
as the sample time. However I get the error that I mentioned above. Could someone please explain this error to me?
Thanks in advance.
Best Regards,
Vamsi

回答 (1 件)

Fangjun Jiang
Fangjun Jiang 2019 年 2 月 6 日
It's a parameter so spescify the sample time as mySimulinkParameter.
  2 件のコメント
Vamsinag Gunti
Vamsinag Gunti 2019 年 2 月 6 日
編集済み: Vamsinag Gunti 2019 年 2 月 6 日
That was the first thing I tried. The block didn't accept the Simulink Parameter. This is the error I get:
Error reported by S-function 'fnccallgen' in 'MyModel/Function-Call Generator': Invalid sample time. Sample time must be a real scalar value or an array of two real values.
Fangjun Jiang
Fangjun Jiang 2019 年 2 月 6 日
編集済み: Fangjun Jiang 2019 年 2 月 6 日
It looks like changing the data type from 'single' to be 'auto' or 'double' will eliminate the error. Worth to repor this to the Mathworks. The error does not make sense.