Affect of low sampling rate on frequency-time diagram in ECG signals

1 回表示 (過去 30 日間)
FSB
FSB 2018 年 9 月 24 日
コメント済み: Adam 2018 年 9 月 24 日
I have ECG signal data recorded with a low sampling rate (61 HZ approx). My focus is to use the time-frequency diagram for further analysis. Now I want to ask what affect does a low sampling rate has on a time frequency diagram (Scalogram)? Also the signal has harmonics (probably due to bluetooth transmission used).Will this also affect the Scalogram?
  1 件のコメント
Adam
Adam 2018 年 9 月 24 日
It just means you won't be able to get any information above 30.5Hz (Nyquist frequency) in your data analysis.