Hello Everybody
I am working on a MATLAB Simulink model for PMSM drive system, my system is controlling the motor's torque. I am facing a problem in linearizing the plant. I have tried to tune PID controller parameters, but the plant cannot be linearized. I don't understand the problem enough to fix it effectively, hereby I tried a lot of things randomly but never worked, in the attached file I tried some manual tuning method but it doesn't result in good dynamic response because a huge overshoot is observed in the output currents and torque :(
Can anyone help in this regard. The Simulink file is attached.
Thanks in advance
Ali Bashabsheh
0 件のコメント
採用された回答
Arkadiy Turevskiy
2018 年 10 月 29 日
Hi there,
Linearization does not work for models with discontinuities such as PWM and power semiconductors.
There are a couple of techniques we recommend:
1. Do ac sweep (frequency response estimation) and use that frequency response for tuning - see this example .
Hope this helps.
Arkadiy
1 件のコメント
Mudit Verma
2020 年 8 月 30 日
Autotuner not working in my model there is no PId gains showing they are showning 0 and only frequencies are showing in display block