three phase fault block

2 ビュー (過去 30 日間)
nur izzati
nur izzati 2011 年 3 月 24 日
回答済み: Degam 2023 年 10 月 13 日
How to use external control fault timing?
I have the algorithm to trip the breaker, but how to apply fault using the external control timing, what block that can be connected to it?

採用された回答

Arnaud Miege
Arnaud Miege 2011 年 3 月 24 日
I assume you are referring to the Three-Phase Fault block from SimPowerSystems. If you look at the documentation for the block, you'll see that it says:
External control of fault timing
If selected, adds a fourth input port to the Three-Phase Fault block for an external control of the switching times of the fault breakers. The switching times are defined by a Simulink signal (0 or 1) connected to the fourth input port of the block.
So the answer is any regular Simulink block, the signal has to be either 0 or 1.
HTH,
Arnaud

その他の回答 (2 件)

nur izzati
nur izzati 2011 年 6 月 9 日
How to know the polarity of saturable current transformer block in matlab simulink?
  2 件のコメント
Arnaud Miege
Arnaud Miege 2011 年 6 月 9 日
Please start a new question rather than add to an existing one. Also, please provide more details: which block are you talking about? what do you mean by polarity? etc... If you have an example model to illustrate your question, even better.
nur izzati
nur izzati 2011 年 7 月 8 日
ok..thanks..I've got the answer already

サインインしてコメントする。


Degam
Degam 2023 年 10 月 13 日
Three phase fault analysis

カテゴリ

Help Center および File ExchangeSources についてさらに検索

製品

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by