Tuning of PIID controller

5 ビュー (過去 30 日間)
Yaser Arafat
Yaser Arafat 2018 年 3 月 2 日
回答済み: Arkadiy Turevskiy 2018 年 8 月 16 日
when I am trying to tune PID controller, I am getting an error message below, The Simulink model abc could not be linearized because the blocks listed below have individual linearizations with A, B, C, or D matrices which are not finite. Either linearize at another operating point or remove the blocks. These blocks are:
abc/Subsystem
  2 件のコメント
M
M 2018 年 3 月 7 日
Is A/B definite ?
Yaser Arafat
Yaser Arafat 2018 年 3 月 8 日
no these are uncertain e.g. Name: 'a' NominalValue: 5 Mode: 'PlusMinus' Range: [4 6] PlusMinus: [-1 1] Percentage: [-20 20] AutoSimplify: 'basic'

サインインしてコメントする。

回答 (1 件)

Arkadiy Turevskiy
Arkadiy Turevskiy 2018 年 8 月 16 日
Hi there,
The way you are trying to model uncertainty in Simulink is not supported. If you define uncertain parameters in Robust Control Toolbox using ureal, you cannot parameterize Simulink blocks with them, as you are trying to do. before you even try tuning a PID controller, try running a simulation, and you will get an error message.
If you are trying to tune a controller that would perform robustly in the presence of uncertainty, please follow the approach explained in this example .

カテゴリ

Help Center および File ExchangeClassical Control Design についてさらに検索

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by