MATLAB Answers

0

Tuning of PIID controller

Yaser Arafat さんによって質問されました 2018 年 3 月 2 日
最新アクティビティ Arkadiy Turevskiy さんによって 回答されました 2018 年 8 月 16 日
when I am trying to tune PID controller, I am getting an error message below, The Simulink model abc could not be linearized because the blocks listed below have individual linearizations with A, B, C, or D matrices which are not finite. Either linearize at another operating point or remove the blocks. These blocks are:
abc/Subsystem

  2 件のコメント

M
2018 年 3 月 7 日
Is A/B definite ?
Yaser Arafat 2018 年 3 月 8 日
no these are uncertain e.g. Name: 'a' NominalValue: 5 Mode: 'PlusMinus' Range: [4 6] PlusMinus: [-1 1] Percentage: [-20 20] AutoSimplify: 'basic'

サインイン to comment.

1 件の回答

回答者: Arkadiy Turevskiy 2018 年 8 月 16 日

Hi there,
The way you are trying to model uncertainty in Simulink is not supported. If you define uncertain parameters in Robust Control Toolbox using ureal, you cannot parameterize Simulink blocks with them, as you are trying to do. before you even try tuning a PID controller, try running a simulation, and you will get an error message.
If you are trying to tune a controller that would perform robustly in the presence of uncertainty, please follow the approach explained in this example .

  0 件のコメント

サインイン to comment.



Translated by