Synchronous Machine parameters rules.

Hi, I had a problem in the assignment of the parameters in the "Synchronous Machine pu Standard" model. The theory indicates that this rule must be given in the parameters.
X_d >= X_q > X_q' >= X_d' > X_q''>= X_d''
T_{do}' > T_{do}''
T_{qo}' > T_{qo}''
but even under this condition, Simulink tells me that the parameters are not consistent. What are the rules for assigning these parameters?

回答 (1 件)

kia Na
kia Na 2018 年 4 月 16 日
編集済み: kia Na 2018 年 4 月 16 日

1 投票

I have the same problem. Did you find out the solution?