If-Else inside Stateflow Chart

59 ビュー (過去 30 日間)
Rashmi Bharadwaja
Rashmi Bharadwaja 2017 年 8 月 18 日
コメント済み: Rashmi Bharadwaja 2017 年 8 月 22 日
Hello all, I am using if-else conditions indside a stateflow chart. When I try to simulate the chart, I get model and coder error. The error says "Chart input data 'signal_name' on left hand side of an expression. I am not able to figure the problem. If anyone knows a solution to this, please let me know.
Thanks in advance.
Cheers, Rashmi

採用された回答

ES
ES 2017 年 8 月 21 日
In that case You have to implement a new output variable (output to Simulink). And to this output variable, you can assign the input variable's value.
You can't set value to an input variable.
  1 件のコメント
Rashmi Bharadwaja
Rashmi Bharadwaja 2017 年 8 月 22 日
This worked. Thanks a lot!

サインインしてコメントする。

その他の回答 (1 件)

ES
ES 2017 年 8 月 18 日
From the error, I think you are trying to assign value to an input signal example {signal_name = xyz}. This is not possible.
What is the exact error message? and when do you get it?
  1 件のコメント
Rashmi Bharadwaja
Rashmi Bharadwaja 2017 年 8 月 21 日
The signals used as inputs to the stateflow chart are also used as conditions and should also be output from the statechart with changing values. The changing ouputs are due to some if-else loops in the chart. At each condition, the output value is different. Do you have any idea how this could be done? I get the above error when I try to simulate the chart. There is a "model error and coder error".

サインインしてコメントする。

カテゴリ

Help Center および File ExchangeSimulink Functions についてさらに検索

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by