- By area vs. opening table — Provide tabulated data of valve openings and corresponding valve passage areas. The passage area is determined by one-dimensional table lookup. You have a choice of two interpolation methods and two extrapolation methods.
- By pressure-flow characteristic — Provide tabulated data of valve openings, pressure differentials, and corresponding flow rates. The flow rate is determined by two-dimensional table lookup. You have a choice of two interpolation methods and two extrapolation methods.
How to parameterize hydraulic valve with given manufacturer data sheet current vs flow rate?
1 回表示 (過去 30 日間)
古いコメントを表示
sanjeev kumar
2017 年 7 月 18 日
コメント済み: Sebastian Castro
2017 年 7 月 19 日
Dear All How do i parameterize the 2 way and 3 way directional valve with given manufacturer data sheet current vs flow rate?
0 件のコメント
採用された回答
Sebastian Castro
2017 年 7 月 18 日
The directional valve blocks have a Model Parameterization option in their dialogs. Two of those values let you enter your own data from, e.g., a datasheet.
From the documentation:
- Sebastian
2 件のコメント
Sebastian Castro
2017 年 7 月 19 日
Current? As in electric current, probably for a valve solenoid or something?
Is that then current vs. flow rate for a specific pressure? Because if so, you can probably back out the valve area as a function of input current...
その他の回答 (0 件)
参考
カテゴリ
Help Center および File Exchange で Upgrading Hydraulic Models to Use Isothermal Liquid Blocks についてさらに検索
製品
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!