フィルターのクリア

SINEWAVE IN SCOPE (simscape)

2 ビュー (過去 30 日間)
Andreas
Andreas 2012 年 4 月 3 日
Hello, I connected an ac voltage source to a voltage sensor and then trough a ps-to-simulink converter to a scope, in order to see the voltage graph. I use an ode23t solver and the only thing I get is a straight line on the x axis (with value ewual to 0). No sinewave looking voltage/ I set simulation time to 0.1. Why is this happening? Do I need to use different blocks? SCOPE is not appropriate for simscape and physical signals?
Thanks

採用された回答

Doug Eastman
Doug Eastman 2012 年 4 月 3 日
To see the sinusoidal voltage variation you need to reduce the step size of the simulation. Go to Simulation -> Configuration Parameters and change the Max step size parameter to be smaller than 1/(2*frequency). For example if the AC frequency is 60 Hz, set the parameter to be 1/120 or 1/240.
  1 件のコメント
K E
K E 2012 年 4 月 3 日
This blog entry may be helpful, http://blogs.mathworks.com/seth/2009/07/14/refining-the-output-of-a-simulation/

サインインしてコメントする。

その他の回答 (1 件)

Andreas
Andreas 2012 年 4 月 9 日
I actually used a really low step like 1e-5 and it workd ok, since the sampling freq increased. I believe that refining is something like interpollating, so it justs recalculates intermediate steps (those that have not been actually sampled).