Simscape: Linear transformer open circuit error
4 ビュー (過去 30 日間)
古いコメントを表示
Hello,
I'm trying to model a full-bridge DC-DC converter in simscape. I have the model built using ideal switches for the mosfets with a simple switching scheme. However, when I run the model, even though the simulation time is 0.05s it comes up with an error that at t=8s, the linear transformer is "open-circuited" because a couple switches are off simultaneously. This off-time should happen and is normal for the switching scheme.
I've attached a couple pictures of my diagram and error.
![](https://www.mathworks.com/matlabcentral/answers/uploaded_files/164363/image.png)
![](https://www.mathworks.com/matlabcentral/answers/uploaded_files/164364/image.png)
Would this error be because of no anti-parallel diodes with the switches?
Thanks!
回答 (1 件)
Joel Van Sickel
2020 年 9 月 2 日
Hello Ryan,
yes, you can create circuits that our tool cannot simulate with this topology. If you include things like diodes and snubbers, this can solve the problem.
Regards,
Joel