フィルターのクリア

PROBLEM SIMULINK CONNECTING BLOCKS

18 ビュー (過去 30 日間)
Andreas
Andreas 2012 年 3 月 30 日
コメント済み: Tejaswini Rao 2017 年 6 月 25 日
I try to connect a ground to the Controlled PWM Voltage block in the -ref port but it cannot be done as, some software or gui problem exists. The same problem appeared with other ports of this block. IS IT SOFTWARE BUG or AM I trying to do something "illegal" given the properties of the blocks I am trying to connect???
I use Simulink 7.6(R2010b)
Thanks

採用された回答

Kaustubha Govind
Kaustubha Govind 2012 年 3 月 30 日
You cannot connect Simulink components to SimScape (SimElectronics) components. Try using the Electrical Reference block instead of the Ground block from the Simulink library.
  2 件のコメント
Andreas
Andreas 2012 年 3 月 30 日
Ok thank you Kaustubha. I did that and i did make it to connect the "ground". I first tried Simulink PS converter for that but it did not work so ELECRICAL REFERENCE block seems to do the job correctly.
Tejaswini Rao
Tejaswini Rao 2017 年 6 月 25 日
Thank you. I was stuck for many days. Your answer helped me.

サインインしてコメントする。

その他の回答 (0 件)

カテゴリ

Help Center および File ExchangeGeneral Applications についてさらに検索

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by