PROBLEM SIMULINK CONNECTING BLOCKS
12 ビュー (過去 30 日間)
古いコメントを表示
I try to connect a ground to the Controlled PWM Voltage block in the -ref port but it cannot be done as, some software or gui problem exists. The same problem appeared with other ports of this block. IS IT SOFTWARE BUG or AM I trying to do something "illegal" given the properties of the blocks I am trying to connect???
I use Simulink 7.6(R2010b)
Thanks
0 件のコメント
採用された回答
Kaustubha Govind
2012 年 3 月 30 日
You cannot connect Simulink components to SimScape (SimElectronics) components. Try using the Electrical Reference block instead of the Ground block from the Simulink library.
2 件のコメント
その他の回答 (0 件)
参考
カテゴリ
Help Center および File Exchange で Composite Components についてさらに検索
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!