No Flow in a basic hydraulic system
7 ビュー (過去 30 日間)
古いコメントを表示
See attached picture. I have modeled a very simple hydraulic system and pressure readings are as expected, but I am reading no flow. I've double-checked all of my parameters and nothing seems out of line. What am I missing here?

2 件のコメント
採用された回答
Sebastian Castro
2016 年 6 月 11 日
I think the problem is your Hydraulic Pressure Sensor is connected in series, and is acting as an infinite resistance. Flow sensors go in series; pressure sensors go in parallel.
Make sure you connect that sensor in parallel, so there is a flow path from the tank all the way through the reference.
- Sebastian