how to build DC wave which have a amplitude of 0 to 360 and frequency 50HZ

hi
i want to generate the waveform which has a amplitude from 0 to 360 and have frequency 50 Hz in simulink. i built the circuit and also achieve the same waveform, but unfortunately when i convert it into HDL language it gives error in "clock" block. so i need to change the logic in which this block not involve and get the same response, kindly help me how i get this waveform by another logic.
with best regards
mudasir ahmed

 採用された回答

Tim McBrayer
Tim McBrayer 2016 年 1 月 15 日

0 投票

Your waveform looks like the output of a counter, counting from 0 to 360 repeatedly. You can use the HDL Counter block, configured appropriately, to create the waveform you need. You'll need 9 bits for the counter width. Specify your initial value (0), step value (whatever time precision you need), and count-to value (360), the sample time (depends on the number of steps you configure), and you will be ready to generate HDL.