Hello Dhilip,
I believe you likely have a mismatched Goto/From tag or visibility setting in your Simulink model. The following troubleshooting steps may help resolve the issue:
  • Firstly, check if a valid ‘Goto’ block exists or not.
  • Ensure the ‘Goto’ block ‘Goto tag’ exactly matches the ‘From’ block Tag.
  • Verify ‘Goto’ block tag visibility allows the ‘From’ to access it.
  • Ensure a ‘From’ connects to only one ‘Goto’ tag source.
For more information, please refer to the following documentations:
  1. https://www.mathworks.com/help/simulink/slref/goto.html
  2. https://www.mathworks.com/help/simulink/slref/from.html
  3. https://www.mathworks.com/help/simulink/slref/gototagvisibility.html
  4. https://www.mathworks.com/help/simulink/gui/unconnectedline.html
Hope this helps!
If the issue persists after trying out the above suggestions, please reach out to Technical Support with any additional details.