Initial condition from external source for discrete integration diuring runtime
1 回表示 (過去 30 日間)
古いコメントを表示
I have a discrite integration with simulink and externaly added the condition:


when changing the value of external source (in my case mec_init_pos) - does it have influence on simulation integration or just for strating simulation and very first initialization of the integration?
0 件のコメント
採用された回答
Fangjun Jiang
2025 年 1 月 17 日
The value of "mec_init_pos" could be constant or dynamic, but in this case, only its value at the begining of the simulation (e.g. t=0) would be taken to set the initial value of the integrator.
When you enable "external reset", then the dynamic value could be taken depending on the external reset signal.
0 件のコメント