Conditionally stop simulation in simulink

33 ビュー (過去 30 日間)
Justina
Justina 2024 年 10 月 11 日
回答済み: Harsh 2024 年 10 月 11 日
Hi,everyone!
I want to detect a signal x in simulink and stop the simulation when it exceeds the limit a. How should I do it?
Thanks for your answer.

採用された回答

Harsh
Harsh 2024 年 10 月 11 日
Hi Ting,
You can connect “compare to constant” block to the signal “x” and then connect the output of that block to “stop simulation” block. In the compare to constant block, you can set the “operator” parameter to “>” and “constant value” parameter to “a”. This setup will stop the simulation when the value of signal “x” exceeds the limit “a”.
Below is an example of “ramp” signal with slope 1 which is set to stop when the signal value exceeds 3.
The output in scope is –
The simulation stops after T=3 when the signal value exceeds 3.
You can check the below documentation links to learn more about the “stop simulation” and “compare to constant” blocks –
I hope this answers your question.

その他の回答 (1 件)

Aquatris
Aquatris 2024 年 10 月 11 日
You can use the stop simulation block.