フィルターのクリア

SimPowerSystems - How to connect three controlled voltage sources delta?

30 ビュー (過去 30 日間)
Will Plaxico
Will Plaxico 2015 年 4 月 28 日
I am modeling a 3 phase grid-connected inverter as an ideal voltage source (fundamental component of voltage only). I have connected three controlled voltage sources delta, but I get the following error:
"following voltage source blocks are in parallel, or are connected in a loop(s) of voltage sources"
As a work around, I have connected a small capacitor to ground from one of the delta terminals but I get the same error. R2013a has a "delta reference" component, but I have 2012a.
Is there another work around I can use to model the delta connected controlled voltage sources?
I am attaching a screenshot of my current connection with my attempted workaround.

採用された回答

Sebastian Castro
Sebastian Castro 2015 年 4 月 29 日
I was able to connect small resistors between the voltage sources to avoid the error. Is this feasible?
In the screenshot below, I used voltage sources of 100 V amplitude, which come out to be 100/sqrt(3) = 57 V in the scope.
- Sebastian
  1 件のコメント
Loknadh Salagamsetty
Loknadh Salagamsetty 2021 年 3 月 15 日
Hi sebastian,
The same model is not working If I try it in Phasor mode. Could you specify why ?

サインインしてコメントする。

その他の回答 (0 件)

カテゴリ

Help Center および File ExchangeConverters (High Power) についてさらに検索

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by