MCC USB-231 compatibility with Simulink

4 ビュー (過去 30 日間)
william
william 2024 年 6 月 28 日
コメント済み: Walter Roberson 2024 年 6 月 28 日
Hello, I am trying to use the data acquisition toolbox to use my USB-231 DAQ inside of my Simulink model. The DAQ shows up inside of MATLAB and I am able to read and write, but inside of Simulink I am unable to access the board from the Data acquisition toolbox's Analog Input/Output. Is there any troubleshooting I can do to get my board to show up or is there some other workaround I need to get it to work in Simulink. Thank you for any help you can give me.

採用された回答

Walter Roberson
Walter Roberson 2024 年 6 月 28 日
The USB-231 is not a supported device. The supported devices are listed at
Perhaps it "works" as an unsupported device.
However,
Note: The support package does not support counter/timer subsystems, digital I/O subsystems,
triggered acquisition, specialized voltage measurements (thermocouple, etc.),
or the use of Simulink data acquisition blocks for Measurement Computing DAQ hardware.
  3 件のコメント
william
william 2024 年 6 月 28 日
Also are you saying that all measurement computing devices cannot use the analog input/output blocks from the data acquisition toolbox in library browser?
Walter Roberson
Walter Roberson 2024 年 6 月 28 日
All Measurement Computing devices cannot use the analog input/output blocks.
I would suggest using a MATLAB Function Block in a discrete model . However, I do not know whether it would be possible to use Acceleration mode with such an arrangement.