I have a Simscape model of an electrical circuit, which I'll refer to as Model A for simplicity. Model A includes standard inputs and outputs typical of Simscape's physical connections. Additionally, I've created a mask for Model A to adjust certain parameters. Now, I need to integrate Model A into a higher-level model, referred to as Model B. Model B consists of multiple instances of Model A, each with variations in the parameters used. Is it possible to construct a referenced model when dealing with physical connections? How?

 採用された回答

Sayan
Sayan 2024 年 3 月 13 日

0 投票

Hi Giovanni,
The Connection Ports do not work with the model references. So you cannot reference Model A and use it in Model B. However, a workaround to this is using the Simulink-PS Converter along with Input port combined as the input and PS-Simulink Converter along with Output port combined as the output to Model A. After this, you can create a subsystem and mask for Model A and reference the system in Model B with a Model reference block.
I have attached an example model you can refer to.
You can find more information on Simulink-PS Converter and PS-Simulink Converter blocks in the following documentation.
Hope this answers the query.

1 件のコメント

Giovanni
Giovanni 2024 年 4 月 12 日
Thank you Sayan! It's clear!