I am studying the Simulink Example Model of PEM Electrolysis System. In the example model, I am finding that the mass of water entering is not equal to the sum of moist Hydrogen and moist Oxygen produced.
Help me understand where the missing mass of water is accounted for and how to measure it.

採用された回答

prithviraj naik
prithviraj naik 2023 年 11 月 15 日
Inside the Cathode gas Channels, is a pipe representing hydrogen gas flow channel.
The W port of the pipe gives the rate of condensation occuring inside the pipe. This is where we can find the missing mass of water.
H2O_in = H2 + O2 + (water vapor in hydrogen) + (condensate in cathode)

その他の回答 (1 件)

Chou
Chou 2024 年 5 月 23 日
Hello, how can I change the temperature of the electrolyzer?