Hi,
I am new to mechanical circuit design and have created a simple circuit as attached. I was expecting to get some velocity measurement but it shows zero value. Could anyone help me with making the right connection for the Translational Motion Sensor? Thanks.
0 件のコメント
採用された回答
Joel Van Sickel
2022 年 9 月 2 日
Hello Sudeep,
it looks like there is a "short circuit" between your force source in and out ports. The 2 port mass block makes it hard to see this, so I have converted them to 1 port mass blocks to show you what is happening under the hood. (the 2 port mass block connects both ports under the hood, so this is the same as what you have modelled) You probably need to delete the line that I highlighted in red. I'm not sure what you are trying to model so I'm not sure this is the correct modification to get the model working.![](https://www.mathworks.com/matlabcentral/answers/uploaded_files/1115190/image.jpeg)
![](https://www.mathworks.com/matlabcentral/answers/uploaded_files/1115190/image.jpeg)
Regards,
Joel