How do I enable the highlighted option programatically ?
0 件のコメント
回答 (1 件)
Yukthi S
2024 年 7 月 24 日
To programmatically toggle Log Events option under PREPARE section of Simulink toolstrip, you can follow these steps. I am using SimpleMessageModel for reference given in the documentation.
1. Enter the following command in command window and open the example model
openExample('simulink/ModelMessageBasedCommunicationFrameworkExample')
2. Get the path name of the current system using gcs.
gcs
More about gcs in the documentation given below:
3. Check the current status of EventLogging parameter using
get_param(gcs,'EventLogging')
4. To enable Log Events, use
set_param(gcs,'EventLogging', 'on')
5. To disable it, use
set_param(gcs,'EventLogging', 'off')