Simulink Error: 'Initial output' of Outport block must be a scalar

21 ビュー (過去 30 日間)
Zangdaarr
Zangdaarr 2015 年 1 月 27 日
回答済み: Eric Duba 2018 年 3 月 2 日
Hi,
I'm trying to update a model from a 2009b version to 2014b and I have gone through several issues.
Now I got the following error:
[QUOTE]The parameter 'Initial output' of Outport block 'MP89/Train1/yout1' must be a scalar when the Outport block is driven by a bus signal[/QUOTE]
Here's a model picture:
Basically, a lot of bus signal are merged into a last bus creator, then a selector lead only the one I want to the output port. The output port has an initial value set in the form [x1;x2;...;xn].
This was working perfectly, but now I got this error, and I do not really understand what is meant by "scalar". I've got a scalar value for every signal in the bus. And all masked values are set to a numeric value.
Thanks for your help

採用された回答

Zangdaarr
Zangdaarr 2015 年 2 月 1 日
Seems it is no longer possible to initialize an output port value when it's driven by a bus. You have to select "inherited".

その他の回答 (1 件)

Eric Duba
Eric Duba 2018 年 3 月 2 日
Initialization is possible see: Specifing initial conditions for bus signals

カテゴリ

Help Center および File ExchangeSchedule Model Components についてさらに検索

製品

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by