How do I use a floating scope? Wired scope to the same signal works fine. With the floating scope, I select the signal through 'Signal Selection' on the scope, run the simulation, see data in the wired scope, see not data in the floating scope and autoscale is 'greyed' out as if no data is there.
How do I get this to work?
0 件のコメント
回答 (3 件)
Paul Costa
2015 年 1 月 8 日
Have you cleared the "Signal storage reuse" check box from the Configuration Parameters dialog? Here's some info from the documentation:
Before using a Floating Scope in a simulation, clear the Signal storage reuse check box in the Optimization > Signals and Parameters pane of the Configuration Parameters dialog box. For more information, see Optimization Pane: Signals and Parameters.
0 件のコメント
Paul Moore
2015 年 1 月 8 日
1 件のコメント
Paul Costa
2015 年 1 月 9 日
Sorry for the trouble. I suggest you send your example model and relevant information (MATLAB version, OS, etc) to support@mathworks.com. They should be able to help you sort this out.
Nathan Zimmerman
2017 年 2 月 9 日
Having a similar issue. Signals from a model reference that are test-pointed won't display. You check them, then you run the simulation and they uncheck themselves. No error/warning messages appear as to why that might be.