Sending input to an embedded block in simulink only at a particular condition
情報
この質問は閉じられています。 編集または回答するには再度開いてください。
古いコメントを表示
Hi,
I wanted to know how can I send a value to an embedded matlab block in simulink only for a particular condition.
I tried using the switch block, but the problem with that is during the times when the condition doesnt satisfy, a DEFAULT value should be sent which doesnt serve my purpose.
I tried using switch case block, but the problem is I am not allowed to use more than one active subsystem incase of switch case block.
To be specific:
I have a simulink model in which, a value (which is clock time at a particular condition which is dependent on output of another block) has to be sent to an embedded matlab block. I do not want to send any other value to the block except at that particular condition. Is there a way to do this? Kindly let me know.
Thanks!!
0 件のコメント
回答 (2 件)
TAB
2011 年 9 月 28 日
1 投票
Place your source of 'value' in 'Enabled Subsystem' and enable this susystem when your condition is satisfied.
Find at Library browser > Ports & Subsystems > Enabled Susystem
0 件のコメント
この質問は閉じられています。
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!