回答済み: Sabin 2022 年 12 月 15 日
I am trying to run the battery simulation through simulink, but I am getting the error as in the title. If only one sub system(13s1p) is added with a configuration block independently, it works, but if it is added to all sub systems, an error occurs as shown in the figure below. It seems that each configuration block needs to be connected again, but I do not know how to do it, so I ask a question.
Could someone help me out? Thanks!

回答 (1 件)

Sabin
Sabin 2022 年 12 月 15 日
Every physical network needs a Solver Configuration block. If you have several physical networks and some Simulink Blocks in between you will have to use one Solver Configuration for each physical network.