Hello,
When I connect two Simscape Tanks (G-TL versions) fluidically so that one tank can transfer liquid to the other, does the block assume that the two blocks are at the same elevation? If so, how can I account for an elevation difference between the bottom of the tanks?
0 件のコメント
回答 (1 件)
Martin
2023 年 10 月 4 日
The best way may be to use the Pipe (TL) block in Simscape Fluids.
It can model elevation changes (constant or variable) in addition to other effects between the two tanks that may be important to your model.