How can i obtain a Narx block in Simulink independent from the sample time of the identified neural network?
2 ビュー (過去 30 日間)
古いコメントを表示
Hi everyone,
I've trained a NARX neural network with an input\output timeseries data sampled at dt = 0.00125.
Then, i've converted the net in a closed loop form thanks to the closeloop function.
Finally, i've generated a Simulink block of this closed net by using gensim function and by specifying a sample time equal to the one of the timeseries used for the identification (so, exactly dt = 0.00125).
Now, i want to use this gensim block in another Simulink model, where the sample time is different than dt = 0.00125 and could be any.
My wish would be to create a block that is independent of the sample time and adapts to the sample time of the simulink model simulation.
0 件のコメント
回答 (1 件)
David Willingham
2021 年 9 月 16 日
Marco,
As the NNet is trained on a specific sample time, it's likely not going to predict well at different sample times. My recommendation is that you'll need to add a rate transistion block before / after the NNet. An example of how to do this can be found here:
David