Units of simulink simulations

3 ビュー (過去 30 日間)
Saraswathi S
Saraswathi S 2021 年 9 月 8 日
コメント済み: Saraswathi S 2021 年 9 月 18 日
I have my dynamical transfer function time constants in minutes. But simulink simulation says its default unit for time is seconds. How can I proceed further.
For sample:
My transfer function: 7/(5s+1). Here 5 is in minutes. And Im designing PID controller for the same. Does the units create any issue in final answers when i run the simulation?

採用された回答

Tanmay Das
Tanmay Das 2021 年 9 月 16 日
Hi,
The default unit for time is seconds in Simulink. You can get a list of all default units from showunitslist command. Transfer function is nothing but the impulse response of a system converted to laplace domain. Here, in this transfer function, 5*60/7 seconds is the time constant according to you but it is 5/7 seconds according to Simulink. So, the response time of the simulink model will be much faster(60 times) as compared to your actual model. Therefore, it is a good practice to change all the units to the default unit before running the simulation.
  1 件のコメント
Saraswathi S
Saraswathi S 2021 年 9 月 18 日
Thank you so much sir

サインインしてコメントする。