Serial Port won't clear after halting debugging

7 ビュー (過去 30 日間)
Fritz Sonnichsen
Fritz Sonnichsen 2011 年 8 月 16 日
コメント済み: Ivan Peric 2018 年 1 月 23 日
I am debugging code using the serial port. If I exit the debug session normally via <shift>F5, I cannot reopen the serial port upon restarting a new debug session. I get the error listed at the bottome of this post. I have to shutdown matlab completely to clear everything.
I can understand why the port is still open (it was not closed upon exiting debug), however I need a way to "clear" it and reopen it after the next debug session.
I issue the 'delete(instrfindall)' at the start of the program but this does not work.
Thanks for any ideas, Fritz
==============================================
??? Error using ==> serial.fopen at 72
Cannot connect to the COM5 port. Possible reasons are another
application is connected to the port or the port does not exist.
Error in ==> spectrometer_monitor at 39
fopen(s);
  2 件のコメント
Ariel
Ariel 2013 年 8 月 27 日
Hello Fritz.
My name is Ariel and I'm dealing the same problem. have you found solution?
Thank you
Ariel
Ivan Peric
Ivan Peric 2018 年 1 月 23 日
You can try this: -right click myCoumputer -properties -device manager -serial -ports -right click your port -disable -enable

サインインしてコメントする。

回答 (1 件)

Adam
Adam 2011 年 8 月 16 日
instrreset
is your friend!
Clear the serial object then issue an instrreset.
  4 件のコメント
Adam
Adam 2011 年 8 月 16 日
From MATLAB documentation on delete:
"Remarks
When you delete obj, it becomes an invalid object. Because you cannot connect an invalid serial port object to the device, you should remove it from the workspace with the clear command."
Adam
Adam 2011 年 8 月 23 日
Did that work?