Hi everyone,
I am using the DAQ toolbox to build a negative feedback system. Anyhow, Is there any method to stop the ai by typing stop(ai); ? I want to stop the data acquisition by hand instead of setting the SamplePerTrigger.
Thank you, Kay

 採用された回答

Chirag Gupta
Chirag Gupta 2011 年 7 月 21 日

1 投票

Hi Kay,
This is possible. Here is some sample code:
ai = analoginpt(....);
% Add channels and set it up
% Use SamplesPerTrigger property to achieve this by setting it to Inf
ai.SamplesPerTrigger = Inf;
start(ai)
% This will continue unless a stop(ai) command is issued
Documentation link for SamplesPerTrigger
You may also want to refer to 'Continuous Acquisition Using Analog Input' demo in the documentation that covers the same scenario

3 件のコメント

Kay
Kay 2011 年 7 月 21 日
when i type stop(ai), the program continued and ignored my command!
What i should do?
Chirag Gupta
Chirag Gupta 2011 年 7 月 21 日
I would suggest looking at the demo! Also, how are you running it? Can you post some sample code?
Chirag Gupta
Chirag Gupta 2011 年 7 月 21 日
After running the stop(ai) command, check the value of ai.Running
or isrunning(ai)