I derived a model that is a Mimo model with 3 inputs and one output. I wanted to design a state feedback controller to control only one of the input because the others are constants that cannot be physically controlled. The approach I addressed is finding the transfer function of the desired control input to the output. Then I convert the system to state space so it turns to be siso system. Is my approach correct?
Thank you

 採用された回答

Azzi Abdelmalek
Azzi Abdelmalek 2014 年 1 月 5 日

0 投票

You can consider your model as SISO with two disturbance signals. Set those two constant signal to 0 and find the transfer function, and convert it to whatever you want (state space representation, or others)