Problem with connection
10 ビュー (過去 30 日間)
古いコメントを表示
Hi... I create a model but appear the next error:
"The following two blocks cannot be connected in series because they are modeled as current sources:
Block 1: Ideal Switch1 Block 2: Subsystem/Controlled Current Source
Add a high-value resistance in parallel with one of the two block. You can also specify high-value resistive snubbers if the blocks have a snubber device."
The Ideal Switch1 and the Subsystem/Controlled Current Source was SimPowerSystems but what resistor i use to correct the error?
1 件のコメント
Kaustubha Govind
2011 年 6 月 27 日
I don't have any experience with SimPowerSystems but you could possibly set a large value for the "Snubber resistance Rs" parameter in the Ideal Switch dialog, as the error message suggests.
採用された回答
Nuno
2011 年 6 月 29 日
4 件のコメント
Arnaud Miege
2011 年 6 月 30 日
OK, try putting a resistor in parallel with the Controlled Current Source and see if that fixes it.
その他の回答 (3 件)
Arnaud Miege
2011 年 6 月 28 日
Just use a Series RLC Branch in parallel with your ideal switch, but keep everything on the SimPowerSystems side (i.e. the resistor should between ports 1 & 2 of the ideal switch).
HTH,
Arnaud
参考
カテゴリ
Help Center および File Exchange で Composite Components についてさらに検索
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!