回答済み
nlarx model initial conditions
You can prefix estimation data (both input and output signals) with nd zeros, where nd = maximum lag in the model. Initial condi...

3年以上 前 | 0

| 採用済み

回答済み
How to force tfest to estimate the process with "only real poles" ?
TFEST cannot guarantee real poles. If you can work with <=3 poles and <=1 zero, try PROCEST. This is a process model estimator...

3年以上 前 | 3

| 採用済み

回答済み
What is the difference between FRD and IDFRD
Both FRD and IDFRD are used to store Freqyency Response Data, that is, the complex frequency response vector (Mag.*exp(i*Phase))...

3年以上 前 | 1

| 採用済み

回答済み
How to estimate the parameter in a customized transfer function
Grey-box identification is an option. You will need to write a function that takes K0 and a0 as inputs, and returns state-space ...

3年以上 前 | 0

回答済み
Minimum input data resolution
Look up Nyquist Sampling Theorem. If you are sampling (hopefully with anti-aliasing) at 1Hz then you cannot theoretically captur...

3年以上 前 | 0

| 採用済み

回答済み
Well-identified fitted process model does not behave like data on simulink
You are almost there. Convert the model into state-space form and use it for simulation. For initial conditions, you will need t...

3年以上 前 | 0

| 採用済み

回答済み
How to calculate the transfer function for a 16 input system?
Try also TFEST. Although you might want to reduce the number of inputs by PCA or PLS analysis.

3年以上 前 | 0

回答済み
nlarx model compare and predict (horizon kept 1) fit totally differs
The difference between (finite-horizon) prediction and simulation is a fundamental concept, something you could read books/artic...

3年以上 前 | 0

| 採用済み

回答済み
Can nlgreyest() estimate open-loop unstable models?
With greyest, either parameterize K matrix using the ODE function, or choose to esitmate it separately by using the "Disturbance...

3年以上 前 | 0

回答済み
System Identification of Closed Loop Data and Unstable Plant
The first reference: [1] System Identification — Theory For the User, Lennart Ljung, Section 13.4-13.5, 2nd ed, PTR Prentice Ha...

3年以上 前 | 0

| 採用済み

回答済み
Accessing the GUI function programatically.
I will repeat Aditya Baru's comment as an answer. The App now supports MATLAB code generation (creating a function from the tas...

3年以上 前 | 1

| 採用済み

回答済み
How to set parameters of Recursive Polynomial Model Estimator in Simulink
The Recursive Polynomial Model Estimator supports single output estimations only.

3年以上 前 | 0

| 採用済み

回答済み
System Identification - Frequency Domain
Make an attempt with stability enforced. opt = tfestOptions('EnforceStability', true); model=tfest(f_data,6,opt) Also, you ...

3年以上 前 | 2

| 採用済み

回答済み
System Identification Toolboox error dialog
What dataset are you using for validation? Does it suply the inputs and outputs that the model needs?

4年弱 前 | 0

回答済み
Does the order (index) of inputs and outputs matter in MIMO system identification?
Yes the order matters since within a given noise level, there are many models that can explain the data. Settings related to sea...

4年弱 前 | 0

| 採用済み

回答済み
System Identification Toolbox: How can we modify the starting parameters for the armax-algorithm?
You can set the A, B, C values explicitly, as in estimatedPolymodel.A = ARCoeff Or, call the IDPOLY constructor with A, B, C p...

4年弱 前 | 0

| 採用済み

回答済み
How to identify a sytem by the System Identification Toolbox that is invertable ?
Tyically yes. If you are estimating state-space model, use "feedthough" name-value pair, as in ssest(Data, order, 'Feedthrough'...

4年弱 前 | 0

回答済み
how to convert a xls to a data ensemble for import into diagnostic feature app
If the data is not too big to fit into MATLAB memory, I would suggest importing it into MATLAB first as a set of tables or timet...

4年弱 前 | 0

回答済み
How can I find initial states for simulation?
Initial states show the effect of the environment on the system. They are not a property of the system to be determined uniquely...

4年弱 前 | 1

| 採用済み

回答済み
System Identification toolbox: how to print estimated ARMA-coefficients for each iteration step in armax-algorithm
Use "full" display option, as in: opt=armaxOptions('Display','full'); estimatedPolymodel=armax(iddata(outputdata,inputdata,tsa...

4年弱 前 | 1

| 採用済み

回答済み
how to use state space model?
If you want to reproduce the response of "predict" by (manual) simulation, you will need to generate the right prediction model ...

4年弱 前 | 1

回答済み
how to plot on the same bode plot a manual function plot() with function bode()?
You could try: G = frd(f1(w),w); % assuming f1(w) is a complex numeric vector bode(G,f2)

4年弱 前 | 0

回答済み
Residual analysis of 100% fit model using system identification toolbox
With simulated data with no noise, it is difficult to read the residual results since there is no baseline noise floor. That is,...

4年弱 前 | 0

| 採用済み

回答済み
Fitting complex function to measurement values
Let X be your data matrix. [~,I]=unique(X(:,1),'stable'); h=X(I,2).*exp(1i*X(I,3)/180*pi); w=X(I,1)*2*pi; G=idfrd(h,w,'Ts',0...

4年弱 前 | 0

回答済み
MISO system identification tool box step response
Yes, use LSIM with input: U = [u, u], where u is a step signal.

4年弱 前 | 0

| 採用済み

回答済み
Merging MISO ARX models
What you need is horizontal concatenation, not MERGE which is about statistical merger of identical (same I/Os and model structu...

4年弱 前 | 0

| 採用済み

回答済み
How to Improve the computation speed for 'ARMAX' function?
If you have access to Parallel Computing Toolbox, you could consider replacing the for-loop with a "parfor" loop. Other things t...

4年弱 前 | 0

回答済み
How to estimate the inital state with an ssest output model
In short, you cannot. SSEST is a black-box identification function (unless you pass in a full initialized @idss model as input),...

4年弱 前 | 0

| 採用済み

回答済み
Why cant I predict kstep ahead when adding System Identification models?
The issue is that algebra on identified models (plus, minus, series, parallel, feedback, inv etc) are not natively supported. Th...

4年弱 前 | 0

| 採用済み

回答済み
System Identification fitness criterion (NRMSE vs NMSE)
A good model should have goodness of fit measure less than 1, indicating that the error (measured_data - model_reponse) is small...

4年以上 前 | 1

| 採用済み

さらに読み込む