NI DAQ USB 6351 problem on win64 platform
3 ビュー (過去 30 日間)
古いコメントを表示
Hi,
I'm trying to acquire data with a NI DAQ USB-6351 card. Executing
ai=analoginput('nidaq','Dev1')
returns an error (since the Legacy interface is not supported in win64?) Can I use the Session-based interface? Running
daq.getDevices
finds no supported devices (it's not a cDAQ, obviously). The USB-6351 works fine in MAX, I have the drivers (NI-DAQmx 9.3) installed (I'm using Matlab 7.12 R2011a and Data Acquisition Toolbox 2.18).
If anyone has any idea how to solve this, I'd greatly appreciate it.
Thanks!
1 件のコメント
xiaobo wu
2011 年 7 月 25 日
what is your OS? windows 7? if the OS is windows 7, try running Matlab as admin under right click menu.
回答 (1 件)
Manisha
2011 年 7 月 11 日
Hi Tomaz,
The prerelease of R2011b Data Acquisition Toolbox now supports many non-compactDAQ devices with Session-based interface.
-Manisha
0 件のコメント