Modbus RS485 Client Read
ライブラリ:
Simulink Coder Support Package for STMicroelectronics Nucleo Boards /
Common
Embedded Coder Support Package for STMicroelectronics STM32 Processors /
STM32F746G-Discovery
Embedded Coder Support Package for STMicroelectronics STM32 Processors /
STM32F769I-Discovery
Embedded Coder Support Package for STMicroelectronics STM32 Processors /
STM32L475VG-Discovery (B-L475E-IOT01A)
Description
In the Modbus RS485 Client Read block, the client device reads data from the register(s) of the server device.
Simulink® Coder™ Support Package for STMicroelectronics® Nucleo Boards and Embedded Coder® Support Package for STMicroelectronics Discovery Boards supports the Modbus® communication protocol over the RS485 network. The client and the server must be connected on the same RS485 network for successful Modbus communication. Each device on the RS485 network is referenced by a unique 8-bit address or identifier.
This table categories the server device registers referenced by the Modbus client device.
| Register Type | Register Size | Allowed Client Operation on Register |
|---|---|---|
| Coil | 1-bit | Read and Write |
| Discrete Input | 1-bit | Read |
| Holding Register | 16-bit | Read and Write |
| Input Register | 16-bit | Read |
The client can perform either a read or a write operation (depending on the register type) on register(s) of a server device.