Power Measurement (Three-Phase, Instantaneous)
Libraries:
Simscape /
Electrical /
Control /
Measurements
Description
The Power Measurement (Three-Phase, Instantaneous) block measures the real
and reactive instantaneous power of an element in a three-phase network. You can calculate the
real and reactive instantaneous power in the abc, alpha-beta-zero
(αβ0), or direct-quadrature-zero (dq0) reference
frame.
To measure single-phase power, use the Power Measurement block instead.
Equations
To use the abc reference frame, set Reference
frame to abc. When you use this frame, the
a, b, and c axes are fixed on the
same plane with a 2π/3 displacement between any two axes. The block
computes the instantaneous power in the abc reference frame by using
these equations:
To use the αβ0 reference frame, set Reference
frame to Alpha-beta-zero. When you use this frame,
the block computes the instantaneous power by using the power-invariant Clarke transform:
To use the dq0 reference frame, set Reference
frame to Direct-quadrature-zero. When you use this
frame, the block computes the instantaneous power by using the Park transform:
Ports
Input
Output
Parameters
References
[1] Akagi, Hirofumi, Yoshihira Kanazawa, and Akira Nabae. “Instantaneous Reactive Power Compensators Comprising Switching Devices without Energy Storage Components.” IEEE Transactions on Industry Applications IA-20, no. 3 (1984): 625–30. https://doi.org/10.1109/TIA.1984.4504460