Hydraulic Cartridge Valve Actuator
(To be removed) Double-acting hydraulic actuator for cartridge valves
The Hydraulics (Isothermal) library will be removed in a future release. Use the Isothermal Liquid library instead. (since R2020a)
For more information on updating your models, see Upgrading Hydraulic Models to Use Isothermal Liquid Blocks.
Library
Valve Actuators
Description
Use the Hydraulic Cartridge Valve Actuator block as a pilot actuator for cartridge valves, as well as pilot-operated pressure and control valves in applications where all the forces, except spring and pressure forces, and flow consumption can be neglected. This block represents a double-acting hydraulic valve actuator driven by three pressures. The actuator drives a valve (spool, poppet, etc.) whose position depends on pressures at ports A, B, and X and the force of the spring. Pressures at ports A and B tend to open the valve, while pressure at control port X together with the spring force act to close it.
Inertial properties of the actuator are accounted for by adding a first order lag between the steady-state and actual valve displacements. The lag is simulated with the combination of the PS Gain and PS Integrator blocks, enveloped by the unity feedback.
The valve remains closed as long as the aggregate pressure force is lower than the spring preload force. The poppet is forced off its seat as the preload force is reached and moves up proportionally to pressure increase until it passes the full stroke.
Connections A, B, and X are hydraulic conserving ports associated with the actuator ports. Connection P is a physical signal port whose output corresponds to poppet displacement. Pressures applied at ports A and B move the poppet in the positive or negative direction, depending on the value of the Actuator orientation parameter, with pressure at port X acting in the opposite direction.
Basic Assumptions and Limitations
The flow consumption associated with the valve motion is assumed to be negligible.
The inertia, friction, and hydraulic axial forces are assumed to be small and are not taken into account.
The clearances between the valve and the washers are not taken into account.
Parameters
- Port A poppet area
Effective poppet area at port A. The parameter value must be greater than zero. The default value is
3.3e-4
m^2.- Port A to port X area ratio
Ratio between poppet areas at port A and port X. The parameter value must be greater than zero. The default value is
0.66
.- Preload force
Spring preload force. The default value is
26
N.- Spring rate
Spring rate. The default value is
1.4e4
N/m.- Poppet stroke
Maximum poppet stroke. The parameter value must be greater than or equal to zero. The default value is
5e-3
m.- Poppet-seat initial gap
Initial gap between the poppet and the seat. The parameter value must be greater than or equal to zero. The default value is
0
.- Time constant
Time constant of the first-order lag. The default value is
0.01
s.- Actuator orientation
Specifies actuator orientation with respect to the globally assigned positive direction. The actuator can be installed in two different ways, depending upon whether it moves the poppet in the positive or in the negative direction when pressure is applied at its inlet. If pressures applied at ports A and B move the poppet in the negative direction, set the parameter to
Acts in negative direction
. The default value isActs in positive direction
.
Ports
The block has the following ports:
A
Hydraulic conserving port associated with the valve inlet.
B
Hydraulic conserving port associated with the valve outlet.
X
Hydraulic conserving port associated with the valve control terminal.
P
Physical signal port that outputs poppet displacement.